Shop with Roton Marine

Shop With Roton Marine

Pacific Yacht Systems now sells products through our Roton Marine branded website with the same trusted service and expert product knowledge you rely on from our team. Visit Roton Marine to browse products and place your order.

Visit Roton Marine

Cable Length for Lithium Battery Bank Split in Two Locations?

Question:

I have a house bank consisting of (4) 300AH LiPoFe batteries split into 2 locations. (2) within three feet of positive and negative bus and the other (2) are 5 - 6 feet away with 4/0 cables.
Is it better to bring farther batteries to the bus bars as not too much difference, or loop them? Electrical expert says its the same. How? - William

Answer:

Thanks for reaching out to PYS.  This a great question and one we are seeing more of with the increase in adaption to LiFeP04.

It is highly recommended when lithium batteries are connected into a bank that common positive and negative bus bars are installed with even length cables from each battery. This is because the internal resistance of a lithium battery is far lower than a traditional flooded lead acid battery and even slight differences in cable lengths may cause individual batteries to charge or discharge at different rates.  In this case there should be (4) x 5 - 6 ft jumpers for positive and negative from each battery regardless of the distance to the bus bar - or in other words, all jumpers must be the same length as the longest run.

Here is a great video on installing lithium systems - https://www.youtube.com/watch?v=j2FUMzN0lLg